Description
Model: M-UPS-001
Digital Display
Input
- Voltage: 220Vac ± 25% (5% changeable)
- Frequency: 50Hz or 60Hz ± 6%
Output
- Voltage: 220Vac (± 5% changeable)
- Frequency: 50Hz or 60Hz ± 1%
- Transfer Time: Approximately 10msec in system check
- Waveform: Sine wave on utility power, square wave on battery operation
Protection
- Overvoltage Load: Fuse for overload and short circuit protection
- Short Circuit: Fuse and limited/disconnected current
Battery
- Battery Type: Sealed lead-acid battery
- Backup Time: 15-35 minutes depending on load
- Protection: Automatic test, discharge protection, and battery fault warning
- Battery Charging: Typically, the battery should be charged once every 3 months, for no less than 6 hours per charge.
Audible Alarm
- Battery Power Supply: Buzzer beeps continuously, red light on
- Low Battery or Overload / Short Circuit: Continuous alarm
Maximum Power 360W
Backup Time Up to approximately 15-35 minutes
Connections
Inputs
- USB-B (printer connection type)
Outputs
- 4 female C13
Dimensions (approx.)
- Width: 87 mm
- Depth: 335 mm
- Height: 143 mm
- Weight: 4.4 kg